Skip to content

nVision Reference Recorder

nVision Reference Recorder Pressure Recorder Temperature Recorder

nVision Reference Pressure Recorder: Precision, Durability, and Portability Combined in a Recorder


The nVision Reference Pressure Recorder: The Ultimate Tool for Accurate and Reliable Calibration and Data Logging

The nVision Reference Pressure Recorder is revolutionizing the handheld calibration industry with its accuracy, durability, and real-time visualization capabilities. This versatile device is accurate enough to replace a traditional deadweight tester, rugged enough to withstand immersion in three feet of water, and portable enough to be used in virtually any calibration setting. Whether working in a lab or out in the field, we designed the nVision recorder to meet your calibration needs with precision and efficiency.

Key Features and Benefits of the nVision Reference Pressure Recorder:

Exceptional Accuracy for Reliable Measurements: The nVision Reference Pressure Recorder provides gauge and absolute pressure measurements up to 15,000 psi (1000 bar / 100 MPa) and differential pressure measurements with an accuracy of up to 0.025% of reading. This high level of accuracy ensures that your measurements are dependable and consistent, making the nVision an ideal choice for a wide range of applications, including oil and gas, manufacturing, and research laboratories.
Real-Time Visualization for Immediate Insights: One of the standout features of the nVision recorder is its ability to visualize measurements graphically in real time. Whether connected to a PC or used independently, the nVision allows you to monitor pressure, switch, voltage, current, and temperature readings while they are recording. This capability makes it easier to identify trends, spot anomalies, and make informed decisions quickly, without the need to sift through complex tables of data or spreadsheets.
Large Data Storage and Fast Sampling Rate: With the capacity to store up to 500,000 data points and a sampling rate of 10 readings per second from two modules, the nVision is designed to handle extensive calibration tasks with ease. This makes it an excellent tool for long-term monitoring and data logging, providing you with comprehensive datasets that are critical for analysis and reporting.
Durability for Harsh Environments: Built to withstand tough conditions, the nVision recorder is rugged enough to operate under extreme environmental stresses. Its robust design ensures reliable performance, even in challenging field conditions. This durability makes the nVision an excellent choice for industries that require on-site calibration, such as marine, petrochemical, and industrial applications.
Temperature Compensation for Consistent Accuracy: The nVision recorder is temperature compensated from -20 to 50°C, ensuring its accuracy remains consistent across various operating environments. This feature is crucial for field applications where ambient temperatures can vary significantly, ensuring that your calibration results are reliable regardless of external conditions.
Easy Data Management and Reporting: The nVision Reference Pressure Recorder can easily connect to a PC, allowing you to view live readings, export data to tamper-proof digital records, and generate detailed reports. This functionality streamlines the recording process, reduces the risk of errors, and simplifies compliance with industry standards and regulations.
Certified Calibration for Peace of Mind: Each nVision recorder comes with a calibration certificate that includes test data at five different temperatures, provided by our A2LA accredited laboratory. This certification ensures that your device meets the highest standards of accuracy and reliability, giving you confidence in your calibration results.

For more information, please contact us.
 

  • Documentation +

  • Video +

    ProductVideoMessage

  • Application Notes +

    • Casing and Tubing Pressure Recording

      Using an nVision reference recorder to record casing and tubing pressure.

    • Gas Industry Measurement

      AMETEK STC has a variety of products designed specifically for the natural gas industry.

    • Hydrostatic Pressure Testing

      The XP2i and nVision are ideal measuring and recording solutions to document pressure testing for the transmission system pipelines.

    • Replacing a Chart Recorder

      The nVision is quickly replacing aging equipment for recording pressure and temperature measurements.

    • Creating a Signed PDF in CrystalControl

      How to create a tamper proof, signed PDF file in CrystalControl.

    • Self Signed Digital ID Set-Up

      How to set-up a digital ID which can be used to sign a tamper proof PDF document.

  • Options +

    • System A & B Pump Systems
      System A
      • AHX Pump System: Includes a T-970 pneumatic hand pump (0 to 580 psi / 40 bar)
      • AXX Pump System: Includes a T-960 pneumatic hand pump (0 to 30 psi / 2 bar)
    • System A & B Pump Systems
      System B
      • BHX Pump System: Includes a T-975 pneumatic hand pump (-25 inHg to 580 psi / - 0.91 to 40 bar)
      • BXX Pump System: Includes a T-965 pneumatic hand pump (-25 inHg to 30 psi / - 0.91 to 2 bar)
    • System C Pump System
      System C
      • CHX Pump System: Includes a T-620H Hydraulic Hand Pump (0 to 5000 psi)
      • CXX Pump System: Includes a T-620 Hydraulic Hand Pump (0 to 3000 psi)
    • System D Pump System
      System D
      • DOX Pump System: Includes a P-018-CPF hydraulic screw pump (0 to 5000 psi, for use with oil)
      • DWX Pump System: Includes a P-018-CPF hydraulic screw pump (0 to 5000 psi, for use with water)
    • System E
      System E
      • EOX Pump System: Includes a P-014 hydraulic bench top pump (0 to 10 000 psi, for use with oil)
    • System F Pump System
      System F
      • FOV Pump System: Includes a T-1 hydraulic bench top pump (0 to 15 000 psi, for use with oil)
      • FWV Pump System: Includes a T-1 hydraulic bench top pump (0 to 15 000 psi, for use with water)
    • System G Pump Systems
      System G
      • GOX Pump System: Includes a GaugeCalHP hydraulic pressure comparator (0 to 15 000 psi, for use with oil)
      • GWX Pump System: Includes a GaugeCalHP hydraulic pressure comparator (0 to 15 000 psi, for use with water)
    • System H Pump Systems
      System H
      • HOX Pump System: Includes a T-975 Pneumatic Hand Pump (-25 inHg to 580 psi / - 0.91 to 40 bar) and a T-620H Hydraulic Hand Pump (0 to 5000 psi / 350 bar)
      • BARO BARO Module – Converts gauge pressure measurement to the absolute scale.
  • Accessories +

      • 5177 Magnetic Hanging Strap.
      • 5535 Soft Carrying Case; durable, padded case with separate pockets for your nVision and accessories (included).
      • 3985 Protective Boot; blue, Skydrol Resistant (included).
      • 3951 USB A to Mini USB Cable for HPC40 Series, HPC50 Series, and nVision (included)
      • 4947 64 ft (20 m) USB A female to USB A male active extension cable. WARNING: Do not use USB interface within a hazardous atmosphere.
      • 3952 Test Lead Kit; two 6’ (1.8 m) 2mm banana jack test leads with multi-purpose clip (included with MA20 module).
      • 3953 RTD Connection Kit; IP67 terminal block connector (RTD module not included).
      • 4126 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-1 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 13 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-3 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 20 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-5 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 26.2 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-15 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-10 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 49.2 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-11 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 80 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-12 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 75 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-13 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-14 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-17 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 50 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-18 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-19 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-16 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 10” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-7 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4491 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 4 mm diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 4 m. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-20 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-2 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 60 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-6 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-23 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 150 x 6 mm diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 1500 mm. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-8 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 150 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-9 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 300 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-21 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-22 50 ft extension for RTD probes, 4 wire.
      • 4748 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
  • Software +

    • CrystalControl

      CrystalControl – Free Software, Communicate, Configure, Data Log (nVision), and Update your nVision, HPC40, HPC50

    • FastCalXP

      FastCalXP – Calibration software that allows you to do a 10 point up and down calibration in less than 3 minutes.

    • JofraCal

      JofraCal (Free) - Calibration software for easy calibration of RTDs, thermocouples, transmitters, thermo switches, pressure gauges, and pressure switches.

    • USB Driver

      USB Driver for XP2i, nVision, and 30 Series

    • UnitCalc

      UnitCalc (Free) – Easy pressure unit calculator. Displays all conversion factors and converted units at the same time. UnitCalc also calculates Head Correction, Gravity Correction, and Air Density