USA - English
This site in other countries/regions:
Select Country to see regional site for Ametek.com
China
Denmark
German
USA
Login
Registered User Login
Toggle navigation
INDUSTRIES
Maritime Industry
Pharmaceutical Industry
Oil and Gas Industry
Chemical and Plastics Industry
Food and Beverage Industry
Power and Energy Industry
Water and Wastewater Industry
PRODUCTS
Pressure
Complete Pressure Systems
Digital Pressure Gauges
Pressure Calibrators
Pressure Recorders
Deadweight Testers
Analog Pressure Gauges
Pressure Transducers and Transmitters
Temperature
Temperature Calibrators
Temperature Indicators
Reference Temperature Sensors
Industrial Temperature Sensors
Process
Multifunction Process Calibrators
Multi-Scanners
mA Loop Calibrators
Pumps and Fittings
Pneumatic Hand Pumps
Hydraulic Hand Pumps
Pressure Comparators
Pressure Fittings
Software
Calibration Software
Logging Software
Configuration Software
Cloud Solutions
KNOWLEDGE
General Calibration
Pressure Calibration
Temperature Calibration
Process Calibration
Videos
Library
Application Notes
Articles
Case Stories
White Papers
SUPPORT
Documentation
Overview Brochures
Accreditations
Product Certifications
Declaration of Conformity
FAQ
Service and Calibration
Product Support - RMA
Register Your Product
Request RMA
Firmware Upgrade
Software Download
Obsolete Products
Looking to Replace your Calibration Equipment?
Terms and Conditions
NEWS
General News
Press Releases
Press Contact
CONTACT
International Distributors
Contact
AMETEK Sales Offices
Temperature Calibration
Low Temperature Freezer Calibration
Dynamic Load Compensation
Calibrating Short and Sanitary Sensors
Dual-Zone Active Control
Efficient Cooling Techniques
The Dry Block Principle
True Temperature Calibration
Correct Use of Inserts
Choose the Correct Insert
Choose the Correct Insert
Using inserts from other calibrators
Often customers believe that they can use inserts from other models of temperature calibrators. Even if the diameter is right, the length might not be. In this case the insert is too tall. This gives a heat flow out of the top of the well and the temperature uniformity will change dramatically.
Using inserts that are too small
Using inserts with diameters that are too small creates another problem. The heat transfer between the well and the insert is insufficient, as the air around the tube has an insulating effect. This will make the temperature very unstable and unable to reach the set value.
This problem also applies to the use of 6 mm and 1/4 in (6.35 mm) sensor holes. Even though this combination may seem to match it gives a very poor heat transfer as the sensors do not have an even contact with the insert.
Using inserts made of the “wrong” material
Home-made inserts can be made in a very professional way with the correct length and size, but the material used for the inserts might cause problems and wrong results. If the specifications e.g. apply to a brass insert, it is not a good idea to use inserts made of aluminum or other materials due to the difference in conductivity.
It is therefore extremely important to use the right material for the inserts.
Using inserts with too short sensor holes
When drilling your own inserts it is a common mistake to make the sensor holes too short. Using this kind of insert may influence the temperature gradient, as the calibrator was originally calibrated at the bottom of the well.
Using inserts without using an insulation plug
All our cooling temperature calibrators are delivered with an insulation plug, to be placed on top of the well. The design requires this device, and the calibrators have also been calibrated with the insulation plug.
There is a large heat flow out of the well, and if the plug is not used during calibration, it will cause problems reaching the set temperature of the calibrator.
Using inserts with the correct size, holes and material
To avoid problems, waste of time and to get the optimum use of your calibrator we recommend that you use inserts from AMETEK Test & Calibration Instruments as they follow our specifications.